To change the cabling lift the modular channel plate and easily open it by hand.
Data center raised floor specifications.
Access floor systems available to support loads ranging from 1 250 to 10 000 lbs per sq.
Also you have access to cabling and wiring in your computer room or data center easily.
Enter some basic information and you will have a complete set of specifications for your raised floor that you can print or copy into your specification program.
Locating switches and patch panels to reduce the need for patching between cabinets and racks is also recommended.
In today s world raised access flooring is primarily used in it data centers and computer rooms where there is a requirement for ufad.
Clearance must be adequate to accommodate interconnecting cables fiber cable raceways power distribution and any piping that is present under the floor.
We offer woodcore raised access floor tiles concrete floor tiles steel floor tiles structural stringer footer supports and data center installation services.
Then reconfigure the computer flooring space or add new equipment.
A telecommunications facility is usually made up of continuous lineups of equipment cabinets.
High strength raised access floor systems designed for the critical data center.
To maximize floor space the cabinets that most data centers use can handle 2 500 3 000 pounds of hardware and the raised floor for data center has to be sturdy enough to hold that weight.
As a professional access floor manufacturer and contractor with years of production experience huiya offers basic raised floor systems in a variety of materials all steel aluminum concrete filled and woodcore and for vary of applications data center computer room server room.
The information center has some additional information too specialized to catagorize.
All cabling and wiring are routed under the floor as well.
The raised floor height should be between 155 mm 6 in and 750 mm 30 in.
If you are new to raised floor terminology we suggest a visit to the glossary.
Welcome to check out huiya raised access floor specifications performances load capacity and technical data.
Floor plans personnel equipment furniture and cabling constantly change in the modern office environment.
200 500 square meters about 400 mm.
Required raised floor height for data center.
When used as an exhaust space refer to vdi 2054 for the floor room air conditioning system standard for floor height.
While light traffic areas are built with the typical 1 000 to 1 500 pound panels.
For processors with multiple channels a minimum raised floor height of 305 mm 12 in is recommended.